NYC DEP Cross Connection ComplianceCall 917-382-4760WhatsAppthefsbtesting@gmail.com

NYS Certified Backflow Testers

Pass your test.
Clear your violations.

Four Strong Backflow Testing handles annual testing, GEN-215B filing, repairs, installations and ECB/OATH violation hearings for buildings of every size across New York City. Fast, cost-effective, and done right the first time.

20+Years in NYC
5Boroughs served

Request a backflow test

Scope, time window and price, usually within one business day.

Prefer to talk? Call 917-382-4760, chat on WhatsApp or email thefsbtesting@gmail.com.

What we do

Backflow services, start to finish

From the yearly test to a DEP installation order, one crew handles your backflow preventer and the paperwork that comes with it.

Includes GEN-215B filing

Backflow Annual Testing

We offer comprehensive annual testing for your backflow device, including filing the GEN-215B report, so you can avoid violations. We make sure your device is in compliance with NYC DEP Cross Connection requirements.

Service details

ECB / OATH representation

Violation Clearance

Our experts handle all your violation needs by representing you at the ECB/OATH hearing. With deep industry knowledge and experience, we negotiate, settle fines, and clear your violations.

Service details

Free re-test after every repair

Repair & Maintenance

Backflow and RPZ devices wear over time and eventually need repair. We specialize in diagnosing and fixing faulty devices, and we back every repair with a free test at the end of the job.

Service details

Per NYC DEP orders

Backflow Installation

Received an order from the NYC DEP? We are your top choice for Backflow RPZ installation. Our certified technicians install all types of backflow devices in accordance with NYC DEP Cross Connection rules.

Service details

How it works

Your annual test in four steps

One visit covers the test and the paperwork. You get a passing device and a filed report.

  1. 1

    Book a visit

    Tell us your building and device. We schedule around your hours.

  2. 2

    Test the device

    A NYS certified tester checks each check valve and the relief valve with a gauge kit.

  3. 3

    Repair if needed

    Worn parts get fixed on the spot, followed by a free re-test.

  4. 4

    File & stay compliant

    We file the results with NYC DEP so your building avoids violations.

Equipment

The equipment we work on

Illustrations of the backflow devices and tools behind every test, repair and installation.

RPZ assembly photo
RPZ assemblyReduced pressure zone assembly: two check valves with a relief valve between them. The most common device we test in NYC.
Double check assembly photo
Double check assemblyTwo independent check valves in series, used where NYC DEP approves a lower-hazard device.
Pressure vacuum breaker photo
Pressure vacuum breakerCommon on irrigation and landscape lines. Tested with the same certified gauge kit.
Differential pressure test kit photo
Differential pressure test kitThe calibrated gauge and hoses our certified testers connect to the test cocks during every test.
Shutoff ball valve photo
Shutoff ball valveThe two shutoff valves isolate the device so it can be tested and repaired.
Repair kit parts photo
Repair kit partsRubber discs, O-rings, springs and seats: the parts that usually wear out and cause a failed test.

Inside the device

How an RPZ protects your water

A reduced pressure zone (RPZ) assembly keeps building water from flowing back into the city main. Here is what we test each year.

Two check valves

Spring-loaded valves let water move toward the building only. We measure the pressure drop across each one.

Relief valve

If pressure in the middle zone rises, the relief valve opens and dumps water out the bottom instead of letting it flow back.

Test cocks

Four small ports where our certified gauge kit attaches. The readings go straight onto your test report.

Initial certification

What is the GEN-215B form?

The GEN-215B is the form for initial certification of a backflow preventer with the NYC DEP. The testing report is completed by a NYS Certified Backflow Prevention Device Tester.

A Professional Engineer or Architect must also sign off on the GEN-215B to certify that the installation matches the approved NYC DEP plans. This can be your originally contracted PE or a PE hired by your NYC Licensed Master Plumber. Settle who that will be before you hire your plumber.

Once signed, the GEN-215B is submitted to the NYC DEP to close out the project. Close-out should happen within 2 years of the original application approval date. If the form is never signed and submitted, the project stays open and a violation can be issued.

Read the full GEN-215B guide

Proudly serving
all five boroughs

For more than 20 years we have delivered top-tier service to buildings of every size across New York City.

Why Four Strong

Done right the first time

Experience, quality and speed, at a price that makes sense for your building.

Experience

Two decades of testing, repairing and installing backflow devices under NYC DEP Cross Connection rules.

Quality

Certified technicians, careful diagnosis, and a free test after every repair we make.

Speed & value

Fast, cost-effective solutions that keep your building compliant and violation-free.

Customer reviews

What NYC building owners say

Google5.0See all reviews

I highly recommend her services! She handles the RPZ testing for my buildings in New York, and she has been wonderful to work with. She is professional, reliable, knowledgeable, and always responsive. She makes the entire process easy and takes care of everything in a timely manner. It's hard to find someone you can count on, and I truly appreciate her excellent service. I look forward to continuing to work with her!

Rotem F.Google review · November 2026

Great job was done by the team. They were very fast and efficient and the price was extremely competitive. They did a new installation and initial testing for us.

Joseph J.Google review · October 2026

Maureen was the best. She tests all my backflow devices.

Lorenzo P.Google review · November 2026

They're great, fast and efficient.

RavGoogle review · November 2026

Leave us a Google review

FAQ

Backflow testing in NYC: common questions

Straight answers about backflow testing, GEN-215B filing and NYC DEP compliance.

What is a backflow preventer?

A backflow preventer is a valve assembly that stops water from a building flowing backward into the public water supply. Common types are the reduced pressure zone (RPZ) assembly, the double check assembly and the pressure vacuum breaker.

How often must a backflow preventer be tested in NYC?

Every year. NYC DEP requires each required backflow prevention device to be tested annually by a NYS certified tester, with the results filed.

What is the GEN-215B form?

The GEN-215B is the NYC DEP form for initial certification of a backflow preventer. The test report is completed by a NYS Certified Backflow Prevention Device Tester, and a PE or Architect certifies the installation matches the approved DEP plans.

What is the penalty for not filing a GEN-215B?

If the GEN-215B is not signed off and submitted to NYC DEP, the project is not closed out and a violation can be issued with a maximum penalty of $1,000.

How long do I have to close out a backflow project?

Project close-out should be completed within 2 years of the original application approval date.

What is an RPZ?

An RPZ, or reduced pressure zone assembly, has two check valves with a relief valve between them. If pressure in the middle zone rises, the relief valve opens and discharges water instead of letting it flow back.

Can you represent me at an ECB/OATH hearing?

Yes. We represent owners at ECB/OATH hearings for backflow violations, negotiate and settle fines, and work to clear the violation.

Is the test after a repair free?

Yes. Every repair we make is backed by a free test at the conclusion of the job.

Business Hours

Monday – Thursday8:00 AM – 5:00 PM
Friday7:00 AM – 2:00 PM
SaturdayClosed
SundayClosed

Hours shown in New York time

Ready to schedule?

Use the request form at the top of the page. We reply with scope, time window and price, usually within one business day.

Request service

Call 917-382-4760
Email thefsbtesting@gmail.com
Find us on Google Maps

Looking for your neighborhood? See all service areas.

CallRequest a test
Chat on WhatsApp